“BC-BC/K” DIRECT READING FLOWMETERS FOR MEDIUM AND LARGE FLOW RATES
The “BC-BC/K” series flowmeters are flow rate measuring devices, suitable for medium and large flow rates of liquid and gaseous fluids. The instantaneous measurement of the flow is read with excellent accuracy on the graduated scale, printed on the calibrated truncated-conical pipe in polycarbonate (makrolon) or polysulphone (non-toxic and unbreakable). The structure can be either flanged or threaded.
CHARACTERISTICS
| Employment | Liquid or gas |
| Accuracy | ±5% del f.s. |
| Maximum pressure | 16 bar for metal structure
8 bar for plastic structure |
| Maximum temperature | 120° C for metal structure
70°C for plastic structure |
| Float | AISI 316 |
| Gasket | NBR – Viton |
| Measuring tube | Polycarbonate or PSU |
TECHNICAL DRAWING/DETAIL
OPTIONALS
- Proximity transducer ALP/1 or ALP/3 for minimum and maxim range alarm
- Polysulfone measuring tube for aggressive liquids and temeperature up to 160°C
- PP structure for temperature up to 100°C and max pressure 6 bar
Standard rates for water 20°C – Air at atmopheric pressure
| TYPE | Water L/h | AIR Nm3/h | B | Threaded connections | Flanged connections | |||||
| Metal | PVC/PP | Metal | PVC | DN | Metal | PVC | DN | |||
| A | A | A | A | |||||||
| BC/3 | 320
420 600 800 |
6
8 10 |
79 | 90 | 372 | 420 | 1/2″
3/4″ 1″ |
504 | 528 | 15
20 25 |
| BC/3b | 1200
1500 |
20 | 79 | 90 | 372 | 420 | 3/4″
1″ |
504 | 528 | 20
25 |
| BC/4 | 2000
2500 3500 |
40 | 89 | 100 | 380 | 428 | 3/4″
1″ |
508 | 532 | 20
25 |
| BC/5b | 4000
5000 6000 |
60 | 112 | 120 | 380 | 428 | 1″1/4
1″1/2 |
508 | 562 | 32
40 |
| BC/K1 | 5000
6000 8000 |
80 | 112 | 120 | 485 | 533 | 1″1/4
1″1/2 |
613 | 667 | 32
40 |
| BC/K2 | 10000
12500 15000 |
130 | 138 | 140 | 481 | 557 | 1″1/2
2″ |
615 | 679 | 40
50 |
| BC/K3 | 20000
25000 30000 37000 45000 |
160
250 |
148 | 150 | 485 | 569 | 2″
2″1/2 3″ |
625 | 679 | 50
65 80 |