DIAPHRAGM TEE JOINT FLOWMETERS “PD”
The PD flowmeter is compacted, light and cheap, with the visual part of the measure range in a piece of transparent and shockproof plexiglas, it is lent where is required the control and the measure of great ranges in small spaces. The maintenance and the cleaning of the plexiglas measurer (not corrosion subjected) is particularly easy. The series “PD” flowmeters are suitable for treatment waters plants, fireproof groups pressurization, wine-making plants, thermotechnical plants, etc.. These flowmeters are suitable to be inserted into flanges, confirm to the normative UNI EN ISO 1092-1.
Maximum working pressure – metallic structures PN 16
- Maximum working pressure – plastic structures PN 16
Precision – ±5%.
IN CONFORMITY WITH UNI 9490 NORMATIVE
GENERAL FEATURES
EMPLOYMENT | Liquid or gas |
ACCURACY | ±5% del f.s. |
MAXIMUM PRESSURE | 16 bar for metal structure
16 bar for plastic structure |
MAXIMUM TEMPERATURE | 70° C |
FLOAT | AISI 316 |
GASKET | NBR |
MEASURING TUBE | PMMA |
MAIN ORIFICE PALATE AND RESTRICTOR | AISI 316 |
STANDARD RATES FOR WATER 20° C
TIPO | Portate max disponibili WATER Mc/h |
UNI PN 16 | ASA 150 | ||||
DN | A | B | DN | A | B | ||
PD-40 | 11 – 15 – 24 – 32 | 40 | 92 | 110 | 1″1/2 | 83 | 107 |
PD-50 | 11 – 25 – 35 – 54 – 70 | 50 | 107 | 120 | 2″ | 102 | 123 |
PD-65 | 25 – 35 – 40 – 54 – 80 – 110 | 65 | 127 | 130 | 2″1/2 | 121 | 127 |
PD-80 | 40 – 70 – 95 – 130 – 180 | 80 | 142 | 138 | 3″ | 134 | 134 |
PD-100 | 80 – 110 – 130 – 180 – 250 | 100 | 162 | 149 | 4″ | 172 | 154 |
PD-125 | 120 – 160 – 220 – 300 – 400 | 125 | 192 | 164 | 5″ | 194 | 165 |
PD-150 | 110 – 180 – 250 – 320 – 400 – 520 | 150 | 218 | 177 | 6″ | 220 | 178 |
PD-200 | 320 – 420 – 600 – 700 – 900 | 200 | 273 | 205 | 8″ | 277 | 201 |
PD-250 | 400 – 500 – 600 – 800 | 250 | 328 | 230 | 10″ |