TURBINE FLOWMETERS WAFER

The flowmeter D-EL is used for liquids, can be mounted to flow vertically and horizontally while keeping a straight section of pipe 10 diameters upstream and 10 diameters downstream. It is manufactured in two versions: the threaded version, and the version to be inserted between flanges wafer. The principle of operation impeller, moved to the flow passage transmits electrical pulses to a Hall sensor, mounted externally, without contact with the liquid, then converted into flow rate, with an accuracy of 2%. It has a totalizer, a compact electronic output 4-20 mA and Analog. In a very simple way you can set two alarms on the entire scale, acting on a membrane keyboard.

CHARACTERISTICS

Measuring Principle Turbine
Principle of sensor Hall effect without contact
Exit Analog/4-20 mA
Display Matrix green LEDs – High Brightness
Alarms Minimum/Maximum programmable
Repeatability frequency 0,5 %
Supply 24 vdc
Absorption 100 mA
Installation Vertical and Horizontal
Temperature 60°C
Material PVC-Moplen
Pression 16 bar
Wafer Connection DN 40 – 50 – 65 – 80 – 100
Threaded Female Connection 1/2″ – 3/4″ – 1″ – 1″1/4 – 1″1/2 – 2″
Totalizer
Ranges M/3 – L/min. – L/h
Accuracy 2/3 %

TECHNICAL DRAWING/DETAIL

Standard rates for water 20°C

TYPE D-EL WAFER UNI PN10
Available Ranges
WATER M3/h
DN-40 3,5 – 35
DN-50 5 – 70
DN-65 10 -110
DN-80 18 – 180
DN-100 25 – 250