TURBINE FLOWMETER G-D 50/60/70 WITH DISPLAY

The flowmeters G 50, G 60 and G 70 are suitable for small and medium flows and are used for liquids or gases. They can be mounted with vertical or horizontal flow, while maintaining a straight pipe equal to 5 DN upstream and downstream of the meter. PMMA is constructed with threaded 1/4 “- 3/8” for the G 50, and 3/8 “- 1/2” for the G 60. (BSP M. PVC / BRASS / STEEL). The operating principle of the turbine, which is moved to the flow passage sends electrical impulses to a Hall sensor, mounted externally, without contact with the liquid, then converted into flow rate. It has a display with totalizer, a compact electronic with Analog output and 4-20 mA, and very simply by acting on the membrane keypad you can set two alarms on the entire scale.

CHARACTERISTICS

Measuring Principle Turbine
Principle of sensor Hall Effect without contact
Exit Analog / 4 – 20 mA
Display Matrix green LEDs – High Brightness
Alarms Programmable Minimum/Maximum
Repeatability frequency 0,5 %
Supply 24 vdc
Absorption 100 mA
Installation Vertical and Horizontal
Temperature 70° C
Material PMMA – Moplen
Pression 10 bar
Threaded Male Connection 1/4″ – 3/8″ – 1/2″
Totalizator M3/h
Range M/3 – L/min. – L/h
Accuracy 2/3 %

TECHNICAL DRAWING/DETAIL

SPACE A

G 50-D 138 mm
G 60-D 148 mm
G 70-D 138 mm

Space body Display

Ø 106 X 52 mm
Threaded Male BSP Available Ranges G 50 for Water
1/4″ – 3/8″ 0,3 – 3 L/min.
1/4″ – 3/8″ 0,5 – 5 L/min.
1/4″ – 3/8″ 0,8 – 8 L/min.
1/4″ – 3/8″ 1 – 10 L/min.
Threaded Male BSP Available Ranges G 60 for Water
3/8″ – 1/2″ 2,5 – 25 L/min.
3/8″ – 1/2″ 3,5 – 35 L/min.
3/8″ – 1/2″ 4 – 40 L/min.
Threaded Male BSP Available Ranges G 70 for Water
1/2″ – 3/4″ – 1″ 5 – 50 L/min.
1/2″ – 3/4″ – 1″ 6,5 – 65 L/min.